The Russell Russvent tile ventilators are designed to offer Architects and Specifiers all the practicalities of roof ventilation with the aesthetics and ease of installation of a normal tile.
Russvent is designed for use for ventilation of the roof space. It can also be used as a soil vent pipe (SVP) or mechanical extract terminal.
The Russvent is available in concrete and plastic in the following profiles
| Concrete RussVent | Plastic RussVent |
| Grampian | Bute3 |
| Highland | Cheviot |
| Galloway | Pennine |
| Lothian | Double Roman |
| Moray | |
| Polden |
Certification
All Russell Roof Tiles concrete fittings are manufactured in accordance with the requirements of BS EN 490 “Concrete Roof Tiles and Fittings-Product specifications” and BS EN 491 “Concrete Roof Tiles and Fitting-Test Methods”.


Technical Information
| Main Tile (Concrete or Plastic) | |
| Free Airflow = 10,000mm2 | |
| Minimum Pitch = 22.5° |
| 2.0 Metre c/c spacing = | 5,000mm2 | ||
| 1.0 Metre c/c spacing = | 10,000mm2 |
| Airflow resistance when used as a SVP/Extract Terminal | ||
| 54m³/Hr | 15 Litres / Sec | 10 Pa |
| 108m³/Hr | 30 Litres / Sec | 42 Pa |
| 216m³/Hr | 60 Litres / Sec | 162 Pa |